xiamen ZONEWU This LoRa wireless Ethylene Oxide (ETO) sensor is a wireless IoT device that can collect, monitor, and transmit data. It is equipped with an ethylene oxide sensor and a temperature and humidity sensor, which can monitor the ethylene oxide concentration, temperature, and humidity data in the environment in real time. The sensor uses high-performance epoxy sensor and microprocessor, accurate detection, stable performance, low power consumption, and supports the standard LoRaWAN protocol, which can transmit data over long distances.
نموذج المنتج :
LW316-ETOوضع امدادات الطاقة :
Battery or External DCتردد :
CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4إصدار MAC :
LoRaWAN 1.0.3طريقة :
OTAA Class A/Cثقل :
120gEnvironmental LoRaWAN Ethylene Oxide (ETO) Sensor
xiamen ZONEWU LoRaWAN Ethylene Oxide (ETO) sensor is a wireless IoT sensor for monitoring ethylene oxide (ETO) gas.
xiamen ZoneWu LoRaWAN Gas Sensor ETO Sensor Features:
This is a wireless IoT sensor that is specifically designed to monitor ethylene oxide gas in the environment, and can also simultaneously collect, monitor and transmit temperature and humidity data.
Using LoRa spread spectrum technology, it supports the standard LoRaWAN protocol and can realize ultra-long-distance wireless communication between terminals, with a very wide data transmission coverage.
Built-in high-performance ethylene oxide sensor and microprocessor, combined with temperature and humidity sensor, the detection data is accurate and the processing speed is fast.
The detection accuracy is high, and the detection of ethylene oxide concentration is very accurate; Stable performance, not easily affected by external interference; Low power consumption, energy-saving and durable.
Safety thresholds can be set in advance according to the environmental situation, and once the concentration of ethylene oxide or temperature and humidity data is abnormal, it will actively alarm and remind.
It is suitable for a variety of scenarios, such as air quality monitoring stations, industrial exhaust emission outlets (to monitor whether the emission of ethylene oxide exceeds the standard), indoor environments (such as hospital disinfection areas), transportation hubs, and other places where ethylene oxide needs to be monitored.
Technical Parameters
Power Supply | 5~28VDC |
Weight | 120g |
Operating Emperature | -20℃~50℃ |
Measuring Principle | Electrochemistry |
Lifespan | <2 years |
Measuring Range |
ETO:(0-100)ppm
Temp:-40~+80 ℃
Humi:0~99.9 %RH
|
Frequency |
CN470/IN865/EU868/RU864/US915/AU915/
KR920/AS923-1&2&3&4
|
Mode | OTAA Class A/C(Default: Class C) |
Reporting cycle |
External power supply:5min(Default reporting cycle)
Report after preheating for 3 minutes when powered on
|
Communication Protocol | LoRaWAN,LoRa TDMA Networking |
Equipment information
(Reference)
|
AppEUI:0000000000000001
DevEUI:aaaa202404150001
AppKey:00001111222233334444555566667777
MAC Version:LoRaWAN 1.0.3
|
Product Applications
1. High precision measurement: This sensor can accurately measure the concentration of ethylene oxide as low as ppm, and the data is very accurate.
2. High sensitivity: the sensor will respond quickly when the environment changes, even if the industrial site situation is complex, it can capture the concentration fluctuation in time.
3. Quick response: The response time is fast, generally less than 150 seconds to react to the change of gas concentration.
4. Wide measurement range: from low concentration to high concentration of ethylene oxide can be measured, and all kinds of environmental monitoring needs can be met.
5. Strong anti-interference ability: can effectively eliminate the interference of hydrogen, ammonia, carbon dioxide, chlorine gas and other gases, and the results are more reliable.
Detailed Images
Common knowledge of ETO
What is ethylene oxide (ETO)? What are the characteristics
Ethylene oxide is a colorless, toxic gas with an ether-like odor (stronger odor at high concentrations), flammable and explosive, and easily soluble in water and organic solvents. It is commonly used as an industrial disinfectant (sterilization of medical instruments) and chemical raw material (production of ethylene glycol, pharmaceutical intermediates, etc.), but it is carcinogenic (listed as a Class 1 carcinogen by the International Agency for Research on Cancer, IARC), and prolonged contact may damage the respiratory system, nervous system, and reproductive system.
What is the safe concentration limit of ethylene oxide in the air
Occupational exposure limit value (PC-TWA, 8-hour workday):
Short-term exposure hazard value:
What are the main sources of ethylene oxide? Why is it easily overlooked
Industrial scenes: medical device sterilization workshop, chemical synthesis factory, printing and dyeing factory, etc.;
· Daily environment:
What interference factors should be paid attention to when detecting the concentration of ethylene oxide
Other gas interference:
Temperature and pressure:
Application Scenarios
Industrial production
Waste gas emission monitoring: Conduct real-time monitoring of industrial waste gas emissions to ensure that waste gases meet emission standards and reduce pollution to the environment.
Environmental inspection
Air quality monitoring helps people understand air quality and protect the environment and health by detecting harmful gases such as sulfur dioxide.
Safety protection
In coal mines and tunnels, gas sensors detect toxic and harmful gases such as methane and warn against accidents.
A:Yes,we can provide you with OEM services and design housings and logos.
3.DO you offer free samples?
A:Sorry,we don't offer free samples. After ordering in bulk, we will deduct the sample fee from the second order.
Why Choose ZONEWU